Distensibility index of inferior vena cava and pulse pressure variation as predictors of fluid responsiveness in mechanically ventilated shocked patients. مؤشر قابلية التمدد للوريد األجوف السفلي وتغير الضغط النبضي كمتنبئ إللستجابة لتحدى السوائل في مرضى الصدمة الخاضعين للتنفس الصناعي

Faculty Medicine Year: 2020
Type of Publication: ZU Hosted Pages: 13
Authors:
Journal: JEMTAC Q- Science Volume:
Keywords : Distensibility index , inferior vena cava , pulse    
Abstract:
Background: Currently, pulse pressure variation (PPV) is considered the gold standard dynamic variable for predicting fluid responsiveness. Distensibility index of inferior vena cava (dIVC) is also considered a good predictor of fluid responsiveness. However, information from literature comparing the performance of both variables is still patchy and insufficient. Therefore, we aimed to investigate the accuracy of dIVC and PPV in predicting fluid responsiveness and compare the predictive power o both techniques. Methods: We conducted our study in shocked patients receiving mechanical ventilation requiring fluid challenge. Hemodynamic variables, such as PPV and dIVC, were recorded before and after fluid challenges. Fluid responders were identified when cardiac output increased more than 15% after the first fluid challenge. Only the non responders received a second fluid challenge (SFC) to define delayed responders. Results: A total of 38 shocked patients were enrolled in this study. Twenty-one patients (55.3%) were fluid responders. The area under the receiver operating characteristic (AUROC) curve of PPV was 0.78 ^ 0.08 with a best cutoff of 10.5 (sensitivity: 76.2%; specificity: 70.6%). The AUROC curve of dIVC was 0.75 ^ 0.07, and the best cutoff value to predict fluid responsiveness was 16.5% with a sensitivity of 71.43% and specificity of 76.5%. Four patients from the non-responder group became responders after the SFC. No statistically significant difference was observed between the predictive performance of PPV and dIVC. Conclusions: Our findings indicate that the performance of PPV for predicting fluid responsiveness was similar to that of dIVC. PPV and dIVC are moderately predictive of fluid responsiveness. Keywords: distensibility index of inferior vena cava, pulse pressure variation, shock, fluid responsiveness
   
     
 
       

Author Related Publications

  • Radwa Mohammed Abdullah Ahmad Hussein, "Resting Left Ventricular Systolic Dyssynchrony and Mechanical Reserve in Asymptomatic Normotensive Subjects with Early Type 2 Diabetes Mellitus", Karger, 2020 More
  • Radwa Mohammed Abdullah Ahmad Hussein, "Safety and efficacy outcomes at 1 year after MitraClip therapy for percutaneous mitral valve repair in patients with severe mitral regurgitation: the Egyptian experience", Springer Open, 2021 More
  • Radwa Mohammed Abdullah Ahmad Hussein, "Tissue tracking of segmental strain as a predictor of provoked dynamic left ventricular outflow tract obstruction", Elsevier, a division of RELX India, Pvt. Ltd., 2022 More
  • Radwa Mohammed Abdullah Ahmad Hussein, ".Low-budget, single-session elimination of CIED pocket infection القضاء على عدوى جيب األجهزة القلبية المزروعة تحت الجلد بأقل التكاليف و في اجراء واحد", Wiley, 2021 More
  • Radwa Mohammed Abdullah Ahmad Hussein, "Ventricular Dyssynchrony based on echocardiographic variables and exercise tolerance After right ventricular pacing: Impact of alternative septal lead locations", Wiley, 2019 More

Department Related Publications

  • Mohammed Ibrahim Amin Ibrahim Musa, "HbA1c And Insulin Resistance As Predictors For The Severity Of Coronary Artery Disease And Systolic Heart Failure In Non Diabetic Patients.", مجله كليه الطب البشري - جامغه الزقازيق, 2014 More
  • Muntasir Mustafa Ahmad, "قيمة الاجابة مضيق الشرايين التاجيين كمؤشر لضيق الشريان الكلوي", لايوجد, 1900 More
  • Muntasir Mustafa Ahmad, "قيمة سملة البطتنة والقيمة الوسطي للشرايين كعامل غير نافذ للتنبؤ بمرض الشريان التاجي", لايوجد, 1900 More
  • Muntasir Mustafa Ahmad, "المسافة بين نقطة التقاء وريقات الصمام الميترالي ومستواة الحلقي كمؤشر ", لايوجد, 1900 More
  • Muntasir Mustafa Ahmad, "قياس حركة ومسدحة الحلقة الشرفية الثلاثية كوسيلة لتنظيم وظيفة القلب ", لايوجد, 1900 More
Tweet