Effect of Normal and Rubberized Concrete Properties on the Behavior of RC Columns Strengthened with EB CFRP Laminates and Welded Wire Mesh under Static Axial Loading

Faculty Engineering Year: 2022
Type of Publication: ZU Hosted Pages:
Authors:
Journal: polymers MDPI Volume:
Keywords : Effect , Normal , Rubberized Concrete Properties , , Behavior    
Abstract:
The huge amounts of old and damaged tires spread worldwide has caused many complex environmental risks. The old tires have been converted to crumb rubber (CR) and tire recycled steel fiber (RSF) to facilitate their use. This study used CR to partially replace natural sand in reinforced (RC) columns. Externally bonded (EB) carbon-fiber-reinforced polymer (CFRP) laminates, welded wire mesh (WWM), and RSF were used to enhance the axial behavior of the tested columns to overcome the concrete deficiencies resulting from the inclusion of the CR instead of natural sand. Eighteen columns were prepared and tested to discuss the effects of strengthening type, CR content, RSF, and strengthening area on the axial behavior of the RC columns. Certain columns were internally reinforced with WWM, while others were externally strengthened with EB CFRP laminates. Partially or fully EB CFRP laminates were used to strengthen the columns. Moreover, one column was cast with NC and 0.2% RSF to investigate the role of RSF in confining the column. The results demonstrated a concrete strength reduction for the rubberized concrete (CRC) as the CR content increased. Conversely, the strengthened columns experienced higher load capacities than the corresponding un-strengthened ones cast with the same concrete mix. Moreover, adding 2% RSF to the NC mix could enhance the column capacity, although it decreased the concrete strength. Furthermore, using two CFRP layers increased the load capacity and ductility of the strengthened columns. The strengthened column cast with 50% CR showed the highest load efficiency (334.3% compared to the un-strengthened one).
   
     
 
       

Author Related Publications

  • Ayman Abdo Mohamed Hessein, "Control of Adjacent Isolated-Buildings Pounding Using Viscous Dampers", Journal of American Science, 2012 More
  • Ayman Abdo Mohamed Hessein, "Damage detection of flexural structural systems using damage index method – Experimental approach", Alexandria Engineering Journal, 2015 More
  • Ayman Abdo Mohamed Hessein, "Damage detection of plate-like structures based on residual force vector", HBRC Journal, 2015 More
  • Ayman Abdo Mohamed Hessein, "Compressive Strength of GUHPFRC Incorporating Fly Ash and Steel Fibers with Dissimilar Configuration", Zagazig University, Faculty of Engineering, 2021 More
  • Ayman Abdo Mohamed Hessein, "Effect of Treated/Untreated Recycled Aggregate Concrete: Structural Behavior of RC Beams", MDPI, 2024 More

Department Related Publications

  • Elsayed saad Abdelsalam Salman, "S. Abdel Salam, H.O. Soliman, E. ELshamy, M.Ismail. “ACTIVE CONTROL OF SEISMICALLY EXCITED STRUCTURES USING POLE ASSIGNMENT METHOD” Scientific Bulletin, Ain Shams Univ., Faculty Of Engineering, Cairo, Egypt, December 31,2005.", Scientific Bulletin, Ain Shams Univ., Faculty Of Engineering, Cairo, Egypt,, 2006 More
  • Elsayed saad Abdelsalam Salman, "S. Abdel Salam, G. Abdelah, and M. El-Kilany, “EXPERIMENTAL AND NUMERICAL STRESS ANALYSIS OF COMPINED STRIP FOOTING”, Proceedings of 11th. Annual Operations Research Conference (First International Confe.), November 28-30, 1988, Zagazig Uni", Proceedings of 11th. Annual Operations Research Conference (First International Confe.), Zagazig Univ., Egypt., 1988 More
  • Elsayed saad Abdelsalam Salman, "M. Mashhour, S. Abdel Salam, and S., ELnaggar, “EFFECT OF LOSS OF SUPPORT ON THE BEHAVIOUR OF COMPINED FOOTING ”, Proceedings of 3rd Arab Structural Eng. Conference, United Arab Emirates Univ., Fac. of Engg., March, 1989, Vol. 3.", Proceedings of 3rd Arab Structural Eng. Conference, United Arab Emirates Univ., Fac. of Eng., Vol. 3., 1989 More
  • Elsayed saad Abdelsalam Salman, "S. Abdel Salam, M. Mashhour, “REPAIR OF 3 BUILDING FOUNDATION IN CAIRO”, Proceedings of Conf. of Building Deterioration in the Arab world, Faculty of Engg., El- Malik Saud Univ., Riyad , K.S.A , March 1992.", Proceedings of Conf. of Building Deterioration in the Arab world, Faculty of Engg., El- Malik Saud Univ., Riyad , K.S.A, 1992 More
  • Elsayed saad Abdelsalam Salman, "S. Abdel Salam, M. Mashhour, and M. Hussein, “THE ANALYSIS OF INTERNAL STRESSES IN A CONTINUOUS FOOTINGUSIN PHOTOELASTICITY” , Bulletin of Fac. of Engg., Cairo Univ., No. 2, Vol. 36, June 1989.", Bulletin of Fac. of Engg., Cairo Univ., No. 2, Vol. 36, 1989 More
Tweet