Recognition and Quantification of Some Monoamines Neurotransmitters

Faculty Science Year: 2016
Type of Publication: ZU Hosted Pages:
Authors:
Journal: Elsevier USA Volume:
Keywords : Recognition , Quantification , Some Monoamines Neurotransmitters    
Abstract:
Three neurotransmitter sensors for dopamine, serotonin, and epinephrine have been developed. Potentiometric sensors for serotonin and epinephrine are novel and first to be introduced. The neurotransmitter potentiometric sensors are based on using dibenzo-30-crown-10 (DB30C10), dibenzo-24-crown-8 (DB24C8), and dibenzo- 18-crown-6 (DB18C6) as ionophores and neutral carriers incorporating in poly(vinyl chloride) matrix membrane plasticized with o-nitrophenyl octyl ether. Sensors based on dibenzo-30-crown-10 show good responses for the dopamine, serotonin, and epinephrine (Type I–III, respectively) with a cationic slope of 57.9 mVdecade@1 and detection limit of 4.0X10@5 molL@1 dopamine, cationic slope of 55.9 mVdecade@1 and detection limit of 4.0X 10@5 molL@1 serotonin, and cationic slope of 54.4 mVdecade @1 and detection limit of 2.0X10@5 molL@1 epinephrine. The sensors based on DB24C8 and DB18C6 (Types IV–IX) show poor responses in terms of calibration range and slope. The effect of the interferents on the response of the sensors reveals a high selectivity for the neurotransmitters over many inorganic cations, ascorbic and uric acids. The useful pH range for the three sensors is 3– 7, the response time is fast (11 s), and the life span is long (2.5 months). Sensors (Types I and III) are successfully used for the quantification of dopamine and adrenaline in pharmaceutical preparations.
   
     
 
       

Author Related Publications

  • Mohamed Alaa Addeen Fathy Mohamed, "Lead(II) Potentiometric Sensor Based on1,4,8,11-Tetrathiacyclotetradecane Neutral Carrier and LipophilicAdditives", USA, 2008 More
  • Mohamed Alaa Addeen Fathy Mohamed, "Liquid Chromatographic and Potentiometric Methods for Determinations of Clopidogrel", USA, 2008 More
  • Mohamed Alaa Addeen Fathy Mohamed, "Novel Sensors for Batch and Flow Injection Analysis of Histamine Based on Crown Ethers", USA, 2012 More
  • Mohamed Alaa Addeen Fathy Mohamed, "Poly (vinyl chloride) matrix membrane sensors for the quantification of olopatadine and oxeladine in pharmaceutical preparations and human plasma", USA, 2019 More
  • Mohamed Alaa Addeen Fathy Mohamed, "New Potentiometric and Spectrophotometric Methods for the Determination of Dextromethorphan in Pharmaceutical Preparations", Japan, 2014 More

Department Related Publications

  • Maher Abdul Rahman Shams al-Din Safty, "catalytic conversion of heavy petroleum distillates using silica-alumina catalyst", لايوجد, 1900 More
  • Maher Abdul Rahman Shams al-Din Safty, "N-oxide and related compounds part 4 some reaction with 1-methyl-z-hydroxy-1-(4-chloro) 3-quinolyl ethylene betaine", لايوجد, 1900 More
  • Maher Abdul Rahman Shams al-Din Safty, "Carbamyle Ethylation of moghat muscles", لايوجد, 1900 More
  • Maher Abdul Rahman Shams al-Din Safty, "chemical modification of moghat muscles via reaction with acrylonitrile in alkaline medium", لايوجد, 1900 More
  • Maher Abdul Rahman Shams al-Din Safty, "normal paraffin distribution in some local crude oils", لايوجد, 1900 More
Tweet